Bangalore
Drive One Wireless Follow Focus Testing
Drive One Wireless follow focus testing as per BS EN 60950, IEC 60950, IS 13252
If you are looking for Drive One Wireless follow focus Testing Laboratory for Drive One Wireless follow focus In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best Drive One Wireless follow focus Testing Laboratory in India.
ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Applicable Standards:
- BS EN 60950
- IEC 60950
- IS 13252
Essential Tests:
- Protection from electric shock and energy hazards
- Fault condition
- Electrical insulation
- Humidity conditioning
- Clearance, creep age distance
- Mechanical strength tests
- Impact test
- Drop test
- Temperature Tests
- Protection against overload and abnormal conditions
- Impulse test
- High Voltage test
For your better understanding, we are going to show you the Drive One Wireless Follow Focus Test report
Learn more about this Drive One Wireless Follow Focus test >
If you’re Buyers Demanding for Drive One Wireless Follow Focus Testing– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]
Get Instant Quotations, Fill the Enquiry form:
Room Heater Testing
ITCIndia Can do Room Heater Testing as per IEC 60335-2-30, IS 302-2-30, ASTM E1509 Standards
If you are looking for Room Heater testing Laboratory for Room Heater In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best Room Heater testing Laboratory in India.
We, “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. The Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Applicable Standards:
- IEC 60335-2-30
- IS 302-2-30
- ASTM E1509
Essential Tests:
- Protection against access to live parts
- Power input and output at operating temperature
- Heating
- Temperature rise
- Leakage current and electric strength
- Transient overvoltage
- Moisture resistance
- Overload protection
- Stability and mechanical hazards
- Mechanical strength
- Provision for earthing
- Insulation resistance
- Creepage and air clearance
Some important test Results are shown in tabular form
Table A:
Cl. 10.1 | TABLE: Power input deviation | P | |||
Input deviation of/at: | P rated | P measured | Allowed Deviation | Remark | |
230V, 50Hz | 2000W | 1930W | +5% & -10% | Within limit | |
Table B:
Cl. 11.8 | TABLE: Heating | P | ||
Test voltages (V) : | At 1.15 * 2000W = 2300 W | – | ||
Ambient (°C) : | 25°C | – | ||
Thermocouple locations | Temp. Measured (oC) | Max. Rise Temp. (oC) | Max Limit (oC) | |
a) Internal Wiring | 72 | 47 | 50 | |
b) External Wiring | 64.1 | 39.1 | 50 | |
c) Handle | 54.5 | 29.5 | 60 | |
d) Switch | 49 | 24 | 30 | |
Table C:
Clause. No. | Test Conducted | Test Conditions | Test requirement | Results |
Cl. 13.2 |
Leakage Current Test |
Motor operated appliance: 1.06 times of rated voltage: Between : Each pole of the supply source and the accessible metal part | Shall not exceed 0.75mA | Pass Imea:24µA |
Cl. 13.3 |
High Voltage Test | Test voltage: : 1000 V Test Duration: 1 min.
Test Part: Between live part and screw on the body. |
Shall withstand without breakdown | Pass
No flashover or break down occur |
Cl. 14 |
Impulse Test (Transient over voltages) |
Transient Overvoltage: 2920V The impulse test voltage is applied three times for each polarity with intervals of at least 1s. | There shall be no flashover. | Pass, No flash over occur. |
Cl. 27.5 |
Earth Contact Resistance Test |
Test Current: 25A
Test Part: Between protective earth terminals and accessible metal Part |
Calculated Earth Contact Resistance from current & drop in voltage shall not exceed 0.1 Ω) | Pass
Rmea:-22.6mΩ |
Table D:
Cl. 29: Clearances, creepage distances and solid insulation | |||
Minimum distance (mm) | Measured distance (mm) | Verdict | |
Clearances | |||
– Basic insulation (at Rated Impulse Voltage 2500) | 1.5mm | >1.5mm | P |
Creepage distances | |||
– Basic Insulation (at Working voltage 250V for pollution Degree 3, Material Group IIIa/IIIb) |
4mm |
>4mm |
P |
For your better understanding, we are going to show you the Room Heater Test report of latest LED in the following:
Learn more about this Room Heater test >
If you’re Buyers Demanding for Room Heater Testing– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!