What is the LM-79 Testing of LED Lights?

Posted on

What is the LM-79 Testing of LED Lights?

LM-79 Testing for LED Lights

LM-79 is an approved method for taking electrical and photometric measurements of SSL products. It covers total flux (light output), electrical power, efficacy, chromaticity, and intensity distribution. The five required metrics on the LED Lighting Facts label come from LM-79 testing results.

ITCIndia Offering you a complete choice of services which include LM 79 Testing, Safety Testing, Electrical Testing, IEC/EN/IS/BS/ISO Testing, IP testing as per IEC 60529 and Cable Gland Testing.

ITCIndia Laboratory has been awarded accreditation by the NABL under the Energy Efficient Lighting Products Program. This includes LM-79 accreditation for Solid State Lighting Luminaires – Total Flux Measurements (Luminous Efficacy) and Solid State Lighting Luminaires –Luminous Intensity Measurements.

Our accreditation also includes IES LM-80:2008 for Solid State Lighting Luminaires-Lumen Maintenance (SSL Life Tests).

ITCIndia laboratory is also on the LED Lighting Facts Approved Labs List.

ITCIndia can do safety testing against below international standard like

  •    IEC 61010-1 : lab instruments
  •    IEC 60204-1 : COntrol panel
  •    IEC 60595 : LED luminary
  •    IEC 61347 : Lamp control gear
  •    IEC 60950 : Information technology equipments
  •    IEC 60601 : Electromedical equipmets
  •    IEC 60065 : Audio video & similar product
  •    IEC 61439 : Low voltage switchgear & control gear assemblies
  •    IEC 60034 : rotating electrical machine and more contact us for more information…

LM-79 Definition and Scope

IES LM-79 is an approved method for testing electrical and photometric measurements of solid-state lighting products. LM-79 contains procedures for performing reproducible measurements of LEDs properties, including: total flux, electrical power, efficacy and chromaticity.

The scope of LM-79 applies to LED products that incorporate control electronics and heat sinks. This covers complete LED luminaires and integrated LED sources. It does not include bare LED chips or LED based products without a light source.

LM-79 testing requires complete luminaire testing on an absolute photometric basis. Typically lighting products are evaluated on a relative photometric basis, where separate tests are done for lamps an luminaires. However, for solid state lighting products the LED lamps typically cannot be separated from their luminaires. The absolute photometric testing required measures the light distribution and light intensity of the complete luminaire.

LM-79 Procedures and Conditions

  • Ambient Conditions
  • Maintain temperature at 25 degrees C +/-1 degree C (within 1M)
  • Mounting – limit thermal transfer
  • Limited air flow
  • Power Supply
  • AC waveshape limit to harmonic RMS of 3%
  • Voltage regulation to +/- 2%
  • Seasoning and Stabilization
  • Testing Orientation
  • Electrical Settings
  • Instrumentation

LM-79 Testing Methods

Integrating sphere systems are used to measure the total luminous flux and color for LM-79. This can be performed with a photometer (total luminous flux) or a spectral radiometer (spectral radiant flux). Utilizing a spectral radiometer and integrating sphere is the preferred method, which derives total luminous flux and color qualities form spectral radiant flux measurements.

Goniophotometer systems are also used for LM-79 testing to measure luminous intensity distribution. The Goniophotometer system tests derive total luminous flux and provide color characteristics including CCT and CRI.

LM-79 Test Outputs and Calculations

  • Total Luminous Flux
  • Luminous Intensity Distribution
  • Electrical Power
  • Luminous Efficacy
  • Chromaticity
  • CCT
  • CRI

For your better understanding, we are going to show you the LM-79 test report of latest LED in the following:

Learn more about this Lm-79 test >

If you’re Buyers Demanding for LM-79 Testing for LED Lights– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

 

Lm-79 Testing | Lm 79 test report | Lm 79 test procedure India

Posted on Updated on

LM-79 Testing, Lm 79 Test report, LM 79 Test procedure, India

ITC India is a NABL accredited laboratory in discipline of Electrical (T-1811), Electronics (T-3509) and photometry (T-3510), serving its satisfied customers for last 5 years. Laboratory is fully equipped with the highly accurate Machines to test LM 79. It owns a Integrating sphere as well as the Goniophotometer.  Qualified and experienced engineer are appointed to perform the desired tests.

Gone are those days when we use incandescence (tungsten filament) or fluorescent (mercury atoms) bulb. They are replaced by LED’s Now; this is an era of SSL (LED) as ……There is innumerable reason for the rise in LED’s which cannot be counted on finger tips. It is beneficial to both USERS as well as to the nation. Its superior features make it so promising that one cannot deny using LED’s.  The features of LED’s are, its low power consumption, digitally controllable,   Low maintenance, Ultra long source life, no UV or IR radiations, No mercury content. SSL uses semiconductors material to convert Electricity into light.  LED’s are non carbon materials.

Efficacy is the quality parameter for LED: it is measure in Lumen per watt. Higher efficacy means high energy efficient. Another quality factor is lifetime and last but not the least is Color rendering Index (CRI). CRI measures the ability of light source to reproduce the color of various objects in comparison with natural light source.

How LM-79 testing can help assess LED luminaries quality and performance?

AS LM79 report provides you with the Photometric as well as electrical parameters with a spectrum Test report. The photometric parameters are luminous flux, Efficacy and Radiant Power, CIE colorimetric Parameters (coordinates Color rendering Index (CRI), color coordinate Temperature (CCT) Duv Value, and light Intensity Distribution .Current, Voltage, Power factor, Power and frequency are the electrical parameters. It Focus on the efficiency and CRI, which are the quality parameter. Efficiency measures how much electrical energy is converting into light energy. Power factor is another electrical metric for LED driver performance and often a key parameter for street lighting due to the large number of these luminaries connected to the power grid.  As far as for lifetime, LM 80 covers that part.

What is the LM-79 test methodology?

 LM 79 is approved method to test Photometric and electrical measurements of Solid state lightning. It describes the procedure and precaution to be observed during measurements. This approved method covers LED based SSL products with control electronics and heat sinks incorporated, that is , those devices that require only AC main power or a DC voltage power supply to operate. This document does not covers SSL products that require external operating circuits, or external heat sink. LM 79 covers SSL product in a form of luminaries (fixture incorporating light source) as well as integrated LED lamps.

Why do we need it?

We need it to access the quality and other parameters due to increasing competition in the market. It provides the efficiency and power factor.   

How is LM-79 different from other test methods used for conventional lighting products?

This approved method is a guide developed for the measurements of SSL products. While many other standards for photometric measurements of light sources and luminaries are available, these standards are separated for measurements of lamps and luminaries. Since the current SSL products are in the form of luminaries or lamps, and LED light source in luminaries are not easily separated as replaceable lamps, these existing standard cannot be applied directly to SSL products. This necessitates the use of absolute photometry. This test method uses absolute photometry where as other standard uses relative photometry in short.

Now lets us clear about relative and absolute photometry.

S.NO Absolute Photometry Relative Photometry
1 Total lumen output of a luminary (bulb with fixture) Total Lumen output of a bare lamp is measured.
2 Method used to measure LED performance. Method used to measure Bare bulb and system performance.
3 Output is relative to an easy measured condition.

 

Output is measured in calibrated units under specific operating and environment conditions, ambient temperature, input voltage and orientation.
4 Specific lamp performance does not matter,

 

Lamps and system performance matters.

 

5 Use for SSL products For NON SSL products

What are the LM-79 test outcomes?

The outcome of the LM 79 is the REPORT providing all the required parameters as per LM 79.

They are ……

  1. CIE colorimetric parameters
  2. Chromaticity coordinate (x)
  3. Chromaticity coordinate (y)
  4. Chromaticity coordinate (u’)
  5. Chromaticity coordinate (v)
  6. Chromaticity coordinate (v’)
  7. Correlated color temperature(Tc)
  8. Duv Value
  9. Color Rendering Index(Ra)
  10. Photometric Parameters
  11. Luminous Flux( Lumen)
  12. Luminous Efficacy( Lm/W)
  13. Radiant Power
  14. Electric Parameters
  15. Input Voltage(V)
  16. Current(A)
  17. Power(W)
  18. Power Factor
  19. Frequency(Hz)
  20. Test information

Ambient Temperature, Stabilization Time, Total Operating Time, Sphere Dia, Photometric method or instrument used Wavelength range in nm of spectroradiometer.

Along with this a SPECTRUM TEST REPORT is also issued.

What are the limitations of LM-79?

  • Chips, Packages, or Modules requiring external heat sinks or operating circuits are not covered
  • Does not state the sampling size.

Is there a future scope for improvement in the LM-79 test?

Yes of course, there is always a scope for improvement in all areas.

Range/criteria of acceptance of CCT, CRI & Lumens may be defining to establish a harmonization of parameters globally.

Top Searches related to LM 79 Tests for LED Tube Lights:

lm 79 standard                                           lm-80

lm 79 test report                                        lm79 and lm80 standards

lm-79 test procedure                            lm 79 testing labs in india

ies lm-80                                                   lm 79 80 standards

How to do LM-79 Testing?                 LM-79 Testing | LM-79 Test Approved Methods

LM-79 Testing Report                          LM-79 Testing Service in India

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

ITC India has around 5000 clients from LED lighting division from All over India.

Get LM 79 Test Report, You can Please feel free to Ask for Quotation.

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

LM-79 Testing for LED Batten | LM-79 Test Reports | lm 79 testing labs

Posted on

LM-79 Testing for LED Batten, LM-79 Test Reports, lm 79 testing labs in India

LM-79 Testing for LED Batten, LM-79 Test Reports, lm 79 testing labs in India

If you Require Testing of LED Batten as per LM-79. ITC India Can Help You! ITC India One of the Best LM-79 testing Laboratory in India. If you have any requirement related LED Batten Testing, you can feel free to contact us. (Call: +91-8196980555)

ITC India NABL Accredited Electrical Safety Testing Laboratory organizing LM 79 testing Testing for LED Batten lights, in all over India. If you are looking for NABL Approved LM-79 Testing Laboratory in your Area, ITC India Can do LM-79 Test for LED Batten lights in a Week.

ITC India NABL Approved Electrical Safety Testing laboratory under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 & T-1811. ITC India Laboratory is fully equipped with high accuracy Measuring Instruments and trained personnel to provide testing and certification Services for Electrical and Electronic equipments. ITC Lab is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

The Testing to be conducted is as follows:-

S.NO. PRODUCT Testing as per standard
1 LED Batten Test to be conducted under LM 79:

a. Measurement of Total Luminous Flux

& Luminous Efficacy

b. Color Characteristics (Chromaticity

Coordinates, Correlated Color

Temperature & Color Rendering Index)

Photometric and Electric Testing as per IES LM-79:

IES LM-79 Testing Approved Method:- Electrical and Photometric Measurements of Solid-State Lighting Products includes three sections:

  • Section 9: Total Flux Measurements
  • Section 10: Luminous Intensity Measurements
  • Section 12: Color Characteristics Measurements. Manufacturers must also submit the IES file containing Section 10 measurements to verify compliance with the zonal lumen density or spacing criteria requirements.

Get Instant Quote, Please send us the following details:

  1. Product Technical Specifications and Brochure
  2. Product Images
  3. Total Number of samples Required: 2

Popular Search about LM-79 Testing:-

  1. How to do LM-79 Testing?
  2. LM-79 Testing | LM-79 Test Approved Methods
  3. LM-79 Testing Report for LED lights, LM-79 Test Requirements & Procedure, lm 79 certificate
  4. LM-79 Testing for LED DownLight | LED Down Light Testing | LM 79 testing labs in India
  5. LED Luminaires Testing Services
  6. LM 79 testing for LED product
  7. LM-79 Testing Service in India

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

ITC India has around 5000 clients from LED lighting division from All over India.

If you are interested to Get LM 79 Test Report, You can Please feel free to Ask for Quotation.

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

 

Electro Medical Equipment Testing India

Posted on

ITC India NABL Accredited laboratory provide Electrical Safety testing against Electro Medical equipments for following types of products/standards: Popular standards for Electro Medical Product testing are IEC 60601-1, IS 13450 etc

General Safety Testing for Electro Medical:

  • Power Input
  • Marking & Instruction
  • External and internal wiring
  • Resistance to environmental Stress
  • Instability hazards
  • Creepage and Clearances distances
  • Determination of Accessible Parts
  • Protective earthing, functional earthing and potential equalization of ME EQUIPMENT
  • Leakage currents and patient auxiliary currents

For List of standards under 60601
List of Major standards under Electro Medical

List of Major standards under Electro Medical
Medical Electrical Equipment – Part 1 : General Requirements For Safety 2 : Collateral Standard : Electromagnetic Compatibility – Requirements And Tests IEC 60601-1-2
Medical Electrical Equipment – Part 2-5: Particular Requirements For The Basic Safety And Essential Performance Of Ultrasonic Physiotherapy Equipment IEC 60601-2-5
Medical electrical equipment – part 2: particular requirements for the safety of electrically operated hospital beds IEC 60601-2-38
Medical electrical equipment – part 2-21: particular requirements for the basic safety and essential performance of infant radiant warmers IEC 60601-2-21
Medical Electrical Equipment – Part 1 : General Requirements For Safety 2 : Collateral Standard : Electromagnetic Compatibility – Requirements And Tests IEC 60601-1-2

Electro Medical Equipment Testing service in Mumbai, Ahmedabad, Pune, Chennai , Delhi, Panchkula, Ludhiana, Ambala

If you have any query regarding Electro Medical Equipment Testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.
We are waiting for your earliest reply. You can call or write us for any clarification
Puneet Sharma | +91.8196980555 | [email protected] | ITC India Pvt. Ltd

Cable Gland Testing

Posted on Updated on

Cable Gland Testing from NABL Accredited Laboratory, Cable Gland Testing from NABL Accredited Lab in India, Get Cable Gland Testing Service from NABL Accredited Laboratory in Mumbai, Chennai, Ahmedabad, Pune, Delhi, Ludhiana

Cable Gland Testing Expert ITC India NABL Accredited Laboratory Provide Cable gland testing As per Bs 6121 & Bs EN 50262
BS 6121:
Specification for mechanical cable glands for elastomer and plastics insulated cables
EN 62444:
Cable glands for electrical installations Test carries out under this standard.

If you are interested for Cable Gland Testing and Certification, you can send us you product technical specification with Images, so that we can provide testing facilities and price.
Puneet Sharma | 08196980555 | E-mail: [email protected]

Submit Your Testing Requirements,Please fill out the Enquiry below:

Solar panel testing As Per IEC 60529

Posted on Updated on

ITC India “Institute of testing & certification pvt ltd” ISO 17025 Accredited Testing Lab  provide Solar Panel Testing Service as per IEC 60529 standard

 

If you have any query regarding earth leakage current testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.

We are waiting for your earliest reply.

You can call or write us for any clarification.

Thanks & Regards,
Puneet Sharma
M: +91.8196980555
E-mail:-([email protected])
ITC India Pvt. Ltd

Submit Your Testing Requirements,Please fill out the Enquiry below:

Cable Gland Testing as per IEC 62444

Posted on Updated on

ITC India Electrical Safety testing Laboratory Provide Testing service on Cable glands (CW), Cable glands (BW), Cable glands (E1W), Cable glands (A2) AS per IEC 62444 standard.

 

If you have any query regarding earth leakage current testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.

We are waiting for your earliest reply.

You can call or write us for any clarification.

Thanks & Regards,
Puneet Sharma
M: +91.8196980555
E-mail:-([email protected])
ITC India Pvt. Ltd

Submit Your Testing Requirements,Please fill out the Enquiry below: