Searches related to Mobile Charger 3 pin Testing

AC DC SMPS Adaptor Testing

Posted on


AC DC SMPS Adaptor Testing as per BS EN 60950, IEC 60950, IS 13252 Standards

If you are looking for AC DC SMPS Adaptor Testing Laboratory for AC DC SMPS Adaptor In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best AC DC SMPS Adaptor Testing Laboratory in India.

ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

Applicable Standards:

  1. BS EN 60950
  2. IEC 60950
  3. IS 13252

Essential Tests:

  1. Input Current
  2. Protections from Hazards
  3. Electrical insulation
  4. Humidity conditioning
  5. Clearance, creep age distance
  6. Mechanical strength tests
  7. Impact test
  8. Drop test
  9. Temperature Tests
  10. Touch Current & protective conductor current
  11. Electric strength
  12. Protection against overload and abnormal conditions

Some important Test’s tables from the issued report ….

Clause. No. Test Conducted Test Conditions Values Measured Results
Cl. 5.1 Touch Current Pluggable type – a maximum

Touch current  Should be Less than 3.5 mA

 

Under 4.53 µA

P
 

 

Cl. 5.2.2

High Voltage Test

 

Test voltage: : 1500 V

Test Duration: 1 min.

Test Part: Between shorted Polarity part and metal foil

 

No flashover/ Breakdown occur

 

P

Table 2

2.10.3 and 2.10.4 TABLE: Clearance and creepage distance  measurements P
Clearance (cl) and creepage distance (cr) at/of/between: Required

Cl (mm)

Measured

Cl (mm)

Required

Cr (mm)

Measured

Cr (mm)

 
Between different polarity 0.4 5.52 0.4 5.52
Between different polarity 0.4 5.52 0.4 5.52

Table 4

4.5, 4.5.4 Thermal Requirement (Touch Temperature limit) P
Measured temperature of parts Maximum allowed temperature (°C) Measured temperature (°C)
External surface of metal part of controller 70°C N/A
PVC Insulation 75°C N/A
Metal 55°C N/A
Mode Switch (Plastic) 85°C 29.5
Note:- Ambient T max (°C)= 25.0

For your better understanding, we are going to show you the AC DC SMPS Adaptor Test report of latest Adaptor in the following:

Learn more about this AC DC SMPS Adaptor test >

If you’re Buyers Demanding for AC DC SMPS Adaptor Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form: