LED Testing

Are You Looking for LED Fitting lumen Efficacy Testing Labs In India?

Posted on

 LED Fitting lumen Efficacy Testing Labs In India
Are You Looking for LED Fitting lumen Efficacy Testing Labs In India?

Are you looking for a LED Fitting lumen Efficacy Testing lab in India? If you said YES! then you’re at the right blog.

If you are looking for LED Fitting lumen Efficacy Testing Laboratory in India, ITC India Can Help You! ITC India one of the best LED Fitting lumen Efficacy Testing Service Provider in India. ITCIndia Can do Glass LED Fitting lumen Efficacy Testing as per IEC/EN Standard

On this blog, I am not just going to pitch you to hire us for my LED Fitting lumen Efficacy Testing services but also going to provide a lot of valuable information on what, why and how we can do LED Fitting lumen Efficacy Testing as per IEC/EN Standard. Call on 08264401091/ 08196980555 for LED Fitting lumen Efficacy Testing laboratories.

Request for LED Fitting lumen Efficacy Testing Report

Why choose ITCIndia For LED Fitting lumen Efficacy Testing?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.

Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.

ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for  LED Fitting lumen Efficacy Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

LED Testing Labs | LED Testing Laboratories – LED Testing Lab Near Me

Posted on

LED Testing Labs | LED Testing Laboratories - LED Testing Lab Near Me
LED Testing Labs | LED Testing Laboratories – LED Testing Lab Near Me

LED Testing Lab, LED Testing, LED Testing laboratories, LED Testing Labs, LED Test Lab

ITC India is having best LED Testing Labs to test LED. We provide all types of testing related to LED Lights. Call at 08196980555 for LED Testing Laboratories.

ITC India test Laboratories provides LED Testing Lab to help customer product development. ITC India has fully equipped LED Testing Lab where we allow customers to characterize LEDs, light engines, and SSL lamps, luminaries and modules etc. We are offering one-stop shopping quality to each customer through our expertise, and state of the art product testing facilities.

Supporting your testing and certification requirements for LED lighting

Significant improvements in the quality and performance of light emitting diodes LED lighting has made it the preferred technology for lamps and lighting products used in consumer, commercial and industrial applications. LED lighting is more energy efficient, and the rapidly growing use of LED lighting will help to reduce energy demand in the coming years. However, LED technology continues to evolve to meet the performance requirements of more demanding applications. As a result, LED testing requirements are changing and expanding to address these issues.

We support the LED industry in the following area:

  • General Testing of LED Arrays, Lamps, Luminaires, Lighting Systems LED Modules and so on
  • General Testing of Lighting parts and components
  • Product Improvement and Engineering Excellence Solutions
  • Quality Assurance and Sourcing Excellence Solutions

What is LED Testing?

Like other lighting products, LED lighting is typically subject to electrical safety, electromagnetic compatibility, and energy efficiency testing. In addition, product performance issues related to the color and intensity of emitted light or exposure to extreme environmental conditions are important considerations for LED lighting products used in demanding applications such as transportation and infrastructure projects. Concerns about the possible health effects from exposure to light generated from LED lighting has also resulted in the introduction of photobiological testing of LED lighting to ensure user safety.

ITC India supports companies from basic research like LED lighting module performance by fully accredited testing in conjunction and pre-compliance testing with our certification partners like EUROTECH, EUROCERT, EUROINSPECTIONS and NABCBL to international standards and performance schemes such as Lighting Facts, DLC , CEC, Eco Design,  Lighting Facts, Energy Labeling and safety schemes like ENEC, CE, GS and UL/ETL Marks. If you are looking LED testing lab then choose ITC India LED Testing Laboratories which is India’s trusted Laboratories.

Searches related to LED Testing Labs

led testing labs in India

ITC India test laboratories

lm 79 testing labs in india

Why LED testing is Important?

LED lighting performance is a primary concern for commercial and industrial customers, and certification to specific performance standards can be used as evidence of compliance with buyer requirements. In addition, demonstrated compliance with the requirements of voluntary energy efficiency schemes, such as the U.S. ENERGY STAR program, can be important factors for marketplace acceptance. Finally, certain tests such as those addressing electrical and photometric safety are generally required for access to major markets, including the U.S. and the EU.

ITC India Can do Photometric Performance Information as per IES Standards:

ITCIndia can provide various services to measure the photometric performance of LED packages, lamps, luminaires and other light sources and products.

ITC India NABL And BIS accredited Photometric  laboratory can do:

ITC India Can do Color Measurements as per IES Standards:

  • IES LM-58:1994- Spectroradiometric Measurements
  • CIE Pub. 13.3:1995- Method of Measuring and Specifying Color Rendering of Light Sources

 ITC India Can do Luminaires Testing as per IES Standards:

  • IES LM-10:1996- Photometric Testing of Outdoor Fluorescent Luminaires
  • IES LM-31:1995- Photometric Testing of Roadway Luminaires
  • IES LM-35:2002- Photometric Testing of Floodlights Using Incandescent Filament or Discharge Lamps
  • IES LM-41:1998- Photometric Testing of Indoor Fluorescent Luminaires
  • IES LM-46:2004- Photometric Testing of Indoor Luminaires Using High-Intensity Discharge or Incandescent Filament Lamps

LED Lights cannot be manufactured with consistent optical properties as a result of the production processes involved. Brightness and color can vary substantially from component to component even in the same production batch. This is why LED Lights have to be tested during production and in their final application. Comprehensive optical characterization is also essential during research and development of LED Lights and for LED Lights -based products.

ITCIndia services for LED Lights include the following tests and certifications:

  • IEC/EN 62471 photobiological safety of lamps and lamp systems
  • IEC/EN 62031 safety requirement of LED module for general lighting
  • IEC/EN 60968 safety requirement of the self-ballasted lamp for general lighting
  • IEC 62560 safety requirement of LED self-ballasted lamp for general lighting which goes beyond 50V
  • IEC/EN 61347-1 safety requirement and general usage of lamp control gear-part1
  • IEC/EN 61347-2-13 lamp control gear-part 2-13: the special requirement of LED module that uses alternating or direct current electronic control gear
  • IEC/EN 60598 the safety requirement of various light fixtures
  • IEC/EN 60838-2-2 miscellaneous lamp sockets-part 2-2: the special requirements of LED module connectors

ITCIndia has developed turnkey solutions for determining luminous intensity, luminous flux, color, spectrum and spatial radiation pattern of LED Lights. The measurement systems generate very accurate results with reliable reproducibility in conformity with the guidelines of the CIE 127 document of the International Commission on Illumination. Instrument Systems uses high-performance spectroradiometers to deliver these solutions.

 ITC India Can do Photometric Measurements per IES Standards:

  1. IES LM-9:1999- Fluorescent Lamps – Total Flux Measurements
  2. IES LM-9:1999- Fluorescent Lamps – Intensity Measurements
  3. IES LM-9:2009- Fluorescent Lamps – Total Flux Measurements
  4. IES LM-9:2009- Fluorescent Lamps – Intensity Measurements
  5. IES LM-45:1991- Incandescent Lamps – Intensity Measurements
  6. IES LM-45:2000- Incandescent Lamps – Total Flux Measurements
  7. IES LM-45:2000- Incandescent Lamps – Intensity Measurements
  8. IES LM-45:2009- Incandescent Lamps – Total Flux Measurements
  9. IES LM-45:2009- Incandescent Lamps – Intensity Measurements
  10. IES LM-51:2000- High-Intensity Discharge Lamps -Total Flux Measurements
  11. IES LM-51:2000- High-Intensity Discharge Lamps – Intensity Measurements
  12. IES LM-66:2000- Single-Ended Compact Fluorescent Lamps – Total Flux Measurements
  13. IES LM-66:2000- Single-Ended Compact Fluorescent Lamps – Intensity Measurements
  14. IES LM-66:2011- Single-Ended Compact Fluorescent Lamps – Total Flux Measurements
  15. IES LM-66:2011- Single-Ended Compact Fluorescent Lamps – Intensity Measurements
  16. EN/IEC 60969, Ed. 1.2: 2001- Self-Ballasted Lamps for General Lighting Services – Performance Requirements

ITC India Can do SSL Color Measurements per IES Standards

  • IES LM-58:1994- Spectroradiometric Measurements
  • CIE Pub. 13.3:1995- Method of Measuring and Specifying Color Rendering of Light Sources
  • IES LM-79:2008 – Solid State Lighting Luminaires – Color Characteristic Measurements
  • IES LM-16:1993- Practical Guide to Colorimetry of Light Sources
  • CIE Pub. 15:2004- Method of Measuring and Specifying Color Rendering of Light Sources

ITC India Can do SSL Photometric Measurements per IES Standards

  • IES LM-79:2008 Solid State Lighting Luminaires – Total Flux Measurements (Luminous Efficacy)
  • IES LM-79:2008 Solid State Lighting Luminaires – Luminous Intensity Measurements

ITC India Can do Electrical Performance Information per IES Standards

ITC India Can do SSL Electrical Measurements per IES Standards:

  • ANSI C82.2:2002- Ballast for Fluorescent Lamps – Methods of Measurement
  • ANSI C82.77:2002- Harmonic Emission Limits – Related Power Quality Requirements for Lighting Equipment

ITC India Can do Electrical Measurements per IES Standards

  • IES LM-9:1999- Fluorescent Lamps – Electrical Measurements
  • IES LM-9:2009- Fluorescent Lamps – Electrical Measurements
  • IES LM-45:2009- Incandescent Lamps – Electrical Measurements
  • IES LM-51:2000- High-Intensity Discharge (HID) Lamps – Electrical Measurements
  • IES LM-66:2000- Single-Ended Compact Fluorescent Lamps – Electrical Measurements
  • IES LM-66:2011- Single-Ended Compact Fluorescent Lamps – Electrical Measurements
  • ANSI C78.375:1997- Fluorescent Lamps – Electrical Measurements
  • ANSI C78.389:2004- High-Intensity Discharge Lamps – Methods of Measuring Characteristics
  • ANSI C78.5:2003- Compact Fluorescent Lamps – Run-up and Start-up Times
  • ANSI C82.2:2002- Ballast for Fluorescent Lamps – Methods of Measurement
  • ANSI C82.6:2005- Ballast for High-Intensity Discharge Lamps – Methods of Measurement

ITC India Can do Life test and Reliability Information per IES Standards

ITCIndia can provide services to measure the performance of lamps, luminaires and other light fittings and products in terms of their lifetime. These include:

ITC India Can do Life Tests per IES Standards

  • IES LM-40:2001- Fluorescent Lamps – Life Test Performance
  • IES LM-47:2001- High-Intensity Discharge Lamps – Life Test Performance
  • IES LM-49:2001- Incandescent Filament Lamps – Life Test Performance
  • IES LM-65:2001- Single-Ended Compact Fluorescent Lamps – Life Test Performance
  • IES LM-65:2010- Single-Ended Compact Fluorescent Lamps – Life Test Performance

NABL And BIS accredited lumen depreciation testing for LED packages, modules and light engines to standards IESNA LM-80-08 and using IESNA TM-21

Future of LED lights:

Since the development of high-brightness blue and white LED Lights, the market for LED light has been booming. LED Lights are used in displays, illuminated advertisements, and lamps. The new light of white LED Lights is already being integrated with cars, aircraft, traffic lights, and classic architectural lighting. It’s no surprise that a brilliant future has been predicted for LED Lights.

Companies like Philips, OsramBajaj and General Electric work round the clock to improve LED light. ITCIndia is cooperating intensively with these companies on metrology. This commitment represents an investment in the future because joining forces in this way provide information on the needs of industry when it comes to measuring LED Lights. ITCIndia also makes an important contribution to the definition of international standards. And this is one of the reasons why ITCIndia is One of the best NABL Approved LED Testing lab in India.

Why choose ITCIndia For LED Testing?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.

Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.

NABL And BIS  accredited performance testing for lumen depreciation of self-ballasted LED lamps, LED lamps with external ballasts and LED luminaires.

ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for Street Light Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

Why Do We Need to LM 79 Test?

Posted on

Why Do We Need to LM 79 Test?

LED is becoming so popular that it has replaced all other lightning sources like candescent lamp, CFL. Manufacturer have shifted to produce LED and making profits by selling low quality products in the market. This can deteriorate the LED business. LM 79 helps to access the LED by giving the photometric parameters and electrical parameters.

LM 79 focus on the absolute photometry, so it directly measures the total lumen of the complete lightning system including fixture, driver etc. LM 79 test report gives electrical and photometric parameter.

Photometric parameter: Luminous flux (lm), efficacy (lm/w), Luminous intensity distribution (candela), chromaticity coordinates, correlated color temperature (CCT), color rendering index (CRI)

Electrical parameter: voltage, current, frequency, power, power factor.

LM 79 Data enable objective product comparison and allows for evaluation relative to performance requirement.

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

What are the limitations of LM-79?

Posted on

What are the limitations of LM-79?

As we all know about the strength of LM 79. Everything has its pros and cons. Let us have a look on the drawbacks of LM 79.

  • LM 79 depicts the parameters of the individual products. So the obtained Parameters cannot be used to access alike products.
  • Other limitation is the sample size. It does not state any sample size. So, the manufacturer provides only one sample instead of supplying more. This thus increases the vulnerability of lesser quality products.
  • This can be used only to determine complete luminary instead of LED used ( as based on absolute photometry) , which can produce different results due to quality of accessories used like glass, thermal effect, lenses etc.

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

What is Relative Photometry?

Posted on

What is relative photometry?

Total Lumen output of a bare lamp is measured in relative photometry   for more clarity; the total luminous flux of the lamp is measured separately without the Fixture. In IES LM-80- 08, IES LM 82-12, the relative photometry is used. The purpose is to find light output, Efficacy, color over temperature for light engines.

Relative photometry can measures:

  • Total luminous flux of the bare lamp
  • Luminous intensity distribution
  • Scale the luminous intensity values by the ratio of the measured lamp lumens to the rated lamp lumens.

Some important features regarding relative photometry:

  1. Relative photometry is performed for luminaries with conventional sources.
  2. Luminaries test is referenced to the luminous Flux measured for bare lamp.
  3. The result produced is in the units of candela per rated lumens( cd/rated lm)
  4. It can also measure the efficiency of luminary.
  5. Normalize ballast factor, Lamp age.
  6. Specific lamp performance doesn’t matter

Relative photometry is not used in SSL with integrated lamps due to many reasons:

  • The LED‘s are difficult to remove from the Luminaries.
  • A large number of LED devices will not work properly without heat sinks provided with luminaries.
  • The thermal environment that the LED devices undergo within the luminary is often radically different from the thermal environment it will practice in its “bare lamp” configuration.

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

What are LM 79 Test Outcomes?

Posted on

What are LM 79 Test Outcomes?

LM-79 is approved test method for electrical and photometric measurements of Solid State Lighting Products. It describes the procedure in measuring total luminous flux, electrical power, luminous intensity distribution, chromaticity under standard conditions. It covers LED based SSL products with control electronics and heat sink incorporated with AC or DC power supply. This does not include LED chips, LED package or LED module but luminaries (fixtures incorporating light source) as well as integrated LED lamps.

The equipment used in LM-79 is integrated sphere and goniophotometer.

Integrating Sphere                          Goniophotometer

The test report shall list all significant data for each SSL product tested together with performance data. The outcomes of the LM-79 test are:

  • Correction factor applied ( e.g. spectral mismatch, self absorption , intensity distribution etc.)
  • Measured total luminous flux( lumen(lm)), input voltage(v), current(a), power(w), Luminous intensity distribution(cd), efficacy(lm/w)
  • Color quantities( chromaticity coordinates, CCT, CRI )
  • Spectral power distribution
  • Bandwidth of spectoradiometer, if spectral distribution and/or color quantities are reported.
  • Statement of uncertainties (if required)
  • Deviation from standard operating procedures, if any.

Here is the link of a test report issued by our prestigious company. LM 79 Test Outcomes

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

What is LM 79 Test methodology?

Posted on

What is LM 79 Test methodology?

LM 79 is an approved method that describes the procedure to be followed and precautions to be observed in performing reproducible measurements of total Luminous flux, electrical power, luminous intensity distribution, chromaticity of Solid-State lighting products for illumination purposes under standard conditions.

LM 79 covers- LED based SSL products with control electronics and heat sinks. Luminaries (fixtures incorporating light source) as well integrated LED lamps.

LM 79 doesn’t cover fixtures without a light source, SSL products that require external operating.

LM 79


Test method for total luminous flux Measurements:

The total luminous flux of SSL product shall be measured with an Integrating Sphere or Goniophotometer. The method may be chosen depending upon what other measurements quantities (color, intensity distribution) need to be measured., the size of SSL products, and other requirements.

The integrating sphere is suited for total luminous flux and color measurements of integrated LED lamps and relative small size LED luminaries. Advantage of using integrating sphere is that it does not requires the “ Dark Room”., and also it is less time consuming.

The Goniophotometer provides measurements of Luminous Intensity Distribution as well as total luminous flux. It can take measurements of larger size luminaries as well as small size luminaries. It has to be installed in Dark Room. Measurements in goniophotometer are time consuming.

  Integrating Sphere Goniophotometer
Conditions No Dark room Dark Room
Size of SSL Small Size luminaries Large size as well as small size Luminaries
Measurements Total Luminous Flux Light Intensity Distribution , Total Luminous Flux
Duration of Test Fast Measurements Time consuming as compared to Sphere photometer.

If you’re Buyers Demanding for Luminaries  Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form: