Room Heater Testing as per IS 302-2-30 in Pune

Room Heater Testing

Posted on

ITCIndia Can do Room Heater Testing as per IEC 60335-2-30, IS   302-2-30, ASTM E1509 Standards

If you are looking for Room Heater testing Laboratory for Room Heater In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best Room Heater testing Laboratory in India.

We, “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811.  The Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

Applicable Standards:

  1. IEC 60335-2-30
  2. IS 302-2-30
  3. ASTM E1509  

Essential Tests:

  1. Protection against access to live parts
  2. Power input and output at operating temperature
  3. Heating
  4. Temperature rise
  5. Leakage current and electric strength
  6. Transient overvoltage
  7. Moisture resistance
  8. Overload protection
  9. Stability and mechanical hazards
  10. Mechanical strength
  11. Provision for earthing
  12. Insulation resistance
  13. Creepage and air clearance

Some important test Results are shown in tabular form

Table A:

 

Cl. 10.1 TABLE: Power input deviation   P
Input deviation of/at: P rated (W) P measured (W) Allowed Deviation Remark
230V, 50Hz 2000W 1930W +5% & -10% Within limit

Table B:

Cl. 11.8 TABLE: Heating P
  Test voltages (V)              : At 1.15 * 2000W = 2300 W
  Ambient (°C)      : 25°C
Thermocouple  locations Temp. Measured (oC) Max. Rise Temp. (oC) Max Limit (oC)
a) Internal Wiring 72 47 50
b) External Wiring 64.1 39.1 50
c) Handle 54.5 29.5 60
d) Switch 49 24 30

Table C:

 

Clause. No. Test Conducted Test Conditions Test  requirement Results
 

 

Cl. 13.2

 

Leakage Current Test

Motor operated appliance: 1.06 times of rated voltage: Between : Each pole of the supply source and the accessible metal part Shall not exceed 0.75mA Pass Imea:24µA
 

Cl. 13.3

High Voltage Test Test voltage: : 1000 V Test Duration: 1 min.

Test Part: Between live part and screw on the body.

Shall withstand without  breakdown Pass

No flashover or break down occur

Cl. 14  

Impulse Test (Transient over voltages)

Transient Overvoltage: 2920V The impulse test voltage is applied three times for each polarity with intervals of at least 1s. There shall be no flashover. Pass, No flash over occur.
 

 

Cl. 27.5

 

Earth Contact Resistance Test

Test Current: 25A

Test Part: Between protective earth terminals and accessible metal Part

Calculated Earth Contact Resistance from current & drop in voltage shall not exceed 0.1 Ω) Pass

Rmea:-22.6mΩ

 

Table D:

Cl. 29:  Clearances, creepage distances and solid insulation
  Minimum distance (mm) Measured distance (mm) Verdict
Clearances
– Basic insulation (at Rated Impulse Voltage 2500) 1.5mm >1.5mm P
Creepage  distances
– Basic Insulation (at Working voltage 250V for pollution Degree 3, Material Group IIIa/IIIb)  

4mm

 

>4mm

 

P

For your better understanding, we are going to show you the Room Heater Test report of latest LED in the following:

Learn more about this Room Heater test >

If you’re Buyers Demanding for Room Heater Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

 

Room Heater Testing as per IS 302-2-30

Posted on Updated on

Room Heater Leakage Current Test as per IS 302-2-30

ITC India Room Heater Testing Laboratory can Do Leakage Current Test as per IS 302-2-30 on Room Heater.

If you have any query regarding Battery Testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.

We are waiting for your earliest reply.You can call or write us for any clarification

Puneet Sharma | +91.8196980555 | [email protected] | ITC India Pvt. Ltd

Submit Your Testing Requirements,Please fill out the Enquiry below: