AC DC SMPS Adaptor Testing
AC DC SMPS Adaptor Testing as per BS EN 60950, IEC 60950, IS 13252 Standards
If you are looking for AC DC SMPS Adaptor Testing Laboratory for AC DC SMPS Adaptor In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best AC DC SMPS Adaptor Testing Laboratory in India.
ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Applicable Standards:
- BS EN 60950
- IEC 60950
- IS 13252
Essential Tests:
- Input Current
- Protections from Hazards
- Electrical insulation
- Humidity conditioning
- Clearance, creep age distance
- Mechanical strength tests
- Impact test
- Drop test
- Temperature Tests
- Touch Current & protective conductor current
- Electric strength
- Protection against overload and abnormal conditions
Some important Test’s tables from the issued report ….
Clause. No. | Test Conducted | Test Conditions | Values Measured | Results |
Cl. 5.1 | Touch Current | Pluggable type – a maximum
Touch current Should be Less than 3.5 mA |
Under 4.53 µA |
P |
Cl. 5.2.2 |
High Voltage Test
|
Test voltage: : 1500 V
Test Duration: 1 min. Test Part: Between shorted Polarity part and metal foil |
No flashover/ Breakdown occur |
P |
Table 2
2.10.3 and 2.10.4 | TABLE: Clearance and creepage distance measurements | P | |||
Clearance (cl) and creepage distance (cr) at/of/between: | Required
Cl (mm) |
Measured
Cl (mm) |
Required
Cr (mm) |
Measured
Cr (mm) |
|
Between different polarity | 0.4 | 5.52 | 0.4 | 5.52 | |
Between different polarity | 0.4 | 5.52 | 0.4 | 5.52 | |
Table 4
4.5, 4.5.4 | Thermal Requirement (Touch Temperature limit) | P | ||
Measured temperature of parts | Maximum allowed temperature (°C) | Measured temperature (°C) | ||
External surface of metal part of controller | 70°C | N/A | ||
PVC Insulation | 75°C | N/A | ||
Metal | 55°C | N/A | ||
Mode Switch (Plastic) | 85°C | 29.5 | ||
Note:- Ambient T max (°C)= 25.0 | ||||
For your better understanding, we are going to show you the AC DC SMPS Adaptor Test report of latest Adaptor in the following:
Learn more about this AC DC SMPS Adaptor test >
If you’re Buyers Demanding for AC DC SMPS Adaptor Testing– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]
Get Instant Quotations, Fill the Enquiry form:
This entry was posted in Adaptor Testing, Electrical Testing Service and tagged AC DC SMPS Adaptor Testing, Adaptor Testing, Ahmedabad, Bangalore, Charge test, Chennai, earth leakage current limits, Earth leakage current Test, Electrical Safety Testing Reference Guide, en 60950-1, how to check if mobile charger is working, how to test a cell phone charger with a multimeter, How To Test a Laptop Adapter, how to test a phone charger with a multimeter, How to test AC adapter?, How to Test an AC Adapter, How to Test If Your Micro-USB Cable, how to test micro usb cable, How to test Mobile Phone Charger, how to test usb amperage, how to test usb cable, how to test usb charger with multimeter, Hyderabad, iec 60950 hipot test, iec 60950 pdf, IEC 60950-1 Information technology equipment – Safety Testing, iec60950-1, India, Kolkata, leakage current test procedure, Major IT equipment safety standard revised, maximum allowable earth leakage current, measure usb current with multimeter, Mobile Adaptor Testing, Mobile Charger 3 pin Testing, Mobile Charger Testing, Mobile Charger Testing as per BS EN IEC IS 60950, Mumbai, New Delhi, pat testing of equipment having high protective, Pune, Searches related to Mobile Charger 3 pin Testing, Searches related to Testing as per BS EN 60950, Surat, Test Laptop AC Power Adapter, TEST REPORT IEC 60950-1, Testing - Product Approvals, Testing as per BS EN 60950, Testing as per IEC 60950, Testing as per IS 13252, USB Charger Testing, USB Mobile Charger Testing, Visakhapatnam.