LED Tube Light Safety Testing as per IEC 60598-2-1 | LM-79 testing | IP Testing India

Posted on

LED Tube Light Safety Testing as per IEC 60598-2-1 | LM-79 testing | IP Testing India

Need to Get LED Tube Light Safety Testing as per IEC 60598-2-1, LM-79 testing, IP Testing in India?

ITCIndia Nabl Accredited Electrical safety Testing Laboratory Providing LED Tube Light Safety Testing and Certification Services as per IEC 60598-2-1, if you are looking for LED Tube Light Safety Testing Laboratory in your Area, you can feel free to contact us, ITCIndia also providing LM-79 testing, and IP testing for LED Tube Lights, if you are interested, we will be happy to assist you.

General Requirements for LED Tube Light Testing and Certification and Procedure:

  1. Classification for LED Tube Light Safety Testing as per IEC 60598-2-1

  • Type of protection Class 0 excluded Class II
  • Degree of protection Requirement: Ordinary IP20
  • Luminaire suitable for direct mounting on normally flammable surfaces.
  • Luminaire not suitable for direct mounting on normally flammable surfaces
  • Luminaire for normal use
  • Luminaire for rough service
  1. Marking for LED Tube Light Safety Testing as per IEC 60598-2-1:

  • Mandatory markings
  • Position of the marking
  • Format of symbols/text
  • Additional information
  • Language of instructions
  • Combination luminaires
  • Nominal frequency in Hz 50/60 Hz
  • Operating temperature
  • Symbol or warning notice
  • Wiring diagram
  • Special conditions
  • Metal halide lamp luminaire – warning
  • Limitation for semi-luminaires
  • Power factor and supply current
  • Suitability for use indoors
  • Luminaires with remote control
  • Clip-mounted luminaire – warning
  • Specifications of protective shields
  • Symbol for nature of supply
  • Rated current of socket outlet
  • Rough service luminaire
  • Mounting instruction for type Y, type Z and some Type X attachments
  • Non-ordinary luminaires with PVC cable
  • Protective conductor current in instruction if applicable
  • Provided with information if not intended to be mounted within arms reach
  • Test with water
  • Test with hexane
  • Legible after test
  • Label attached
  1. Construction
  2. Creepage distances and clearances
  3. Provision for earthing
  4. Screw terminals
  5. Screw less terminals and electrical connections
  6. External and internal wiring
  7. Protection against electric shock
  8. Endurance test and thermal test
  9. Resistance to dust, solid objects and moisture
  10. Insulation resistance and electric strength
  11. Resistance to heat, fire and tracking

And etc………

Please give us the following information to quote you:

  1. LED Tube Light photograph
  2. Intended use of the LED Tube Light
  3. Technical specification of the LED Tube Light.

We hope to have the opportunity to work with you in the future

For Further Clarification Please feel free to Contact Now! We would be happy to assist you

Mr. Puneet Sharma | Call: 08196980555 | Email: [email protected]

Get Instant Quotations for LED Tube Light Testing, Please Fill the Enquiry form below:

Photometry Training Course In India

Posted on Updated on

Photometry Training Course Brochure

PHOTOMETRY TRAINING COURSE

Photometric Testing helps you to understand the basic concepts of light, LED and solid state lighting specifications. Our regular 2-day training course in photometry, Colorimetry and light measurement will help you to understand LED and lighting specifications and avoid common misconceptions that come to one’s mind while operating/testing these devices. We will show you how to correctly measure and express the performance of your lighting products and the training will benefit technical and marketing staff alike.

Training Insights:

Lighting is an exciting and rapidly developing area -LEDs and solid-state lighting promise not only energy efficiency but also designs. Yes!! LED specifications are often mistrusted and sometimes misleading too.

Developed in partnership with measurement equipment specialists Eurotech Assessment and Certification Services Pvt. Ltd. training course in Photometry, Colorimetry AND Light measurement through Gonio-photometer and integrating sphere help you to understand LED and lighting specifications, to separate the reality from fiction in LED specifications and show you how to measure and express the output of various lighting products and ways to interpret its results.

Our Training presents what is often thought as highly complex technical subjects in an easily understood way and combines a review of the theory of light and color measurement with practical, hands-on experience with the latest photometry equipment. Our state-of-the-art training lab contains integrating sphere, LED Power driver tester, Test Panel, Vitric, HV Tester, ECR, Gonio-photometers, Spectro-radiometer and many more.

Practical exercises included in the Photometry Training involve measuring the luminous flux-color temperature and color rendering of an LED fitting, a demonstration of the inverse squared law, and measurement through integrating sphere for the creation of data file.

COURSE DETAILS:

Module 1: Basic Concepts

 Light, Materials and the Human Visual System Light and the electromagnetic spectrum, Vision, S:P ratio and BS EN 5489-1:2013,Reflectance – specular, diffuse and scatter, Lambert Cosine Law.

Module 2: Photometry

 Introduction, Angle, Solid Angle, Luminous Intensity, Luminous flux, Illuminance, Photometer, Energy efficiency metrics-LOR, luminous efficacy & energy efficiency index,  The inverse squared law, Photometric field – near-field versus far-field measurements, Photometric applications

Module 3: Colorimetry

 Introduction, Components of Colorimetry, Color vision   and
Tristimulus theory, CIE color model, CIE color spaces and chromaticity, Color temperature & correlated color temperature, CIE standard illuminants, Dominant wavelength & purity, Color difference sensitivity & metrics.

Module 4: Integrating Sphere Measurements

Introduction, choosing the correct size sphere, Calibrating the integrating sphere, Correcting for sample absorption, Uncertainty and sources of error, precautions.

Module 5: Goniophotometry & Standard Photometric Data

Introduction, Standard photometric data Files, photometric data types, Goniophotometry Types.

About photometric Testing:

Eurotech Assessment and Certification Services Pvt. Ltd. is an independent test lab specialising in the measurement of light, lighting products and the optical properties of materials. We provide precision measurements of the color and brightness of LEDs, luminaires, solid state lighting, lamps, signs, and displays.We help you to save time and money in bringing your next generation of products to market.

 

Eurotech Assessment and Certification Services Pvt. Ltd.has invested in the latest, state-of-the-art photometric, spectroradiometric and goniophotometric equipment to ensure that our measurements are accurate, repeatable, traceable and conform to the latest international standards. This investment has resulted in the creation of what is probably the most up-to-date, independent lighting test laboratory in India. With years of experience, we have absolute confidence in our results.

You you are Interested, Please fill out the Enquiry form below:

LM-79 Testing for LED Flood lights, LM-79 Procedure, lm 79 Test Report

Posted on

LM-79 Testing for LED Flood lights

LM-79 Testing for LED Flood lights

If you are looking for LM-79 Testing for LED Flood lights, ITC India NABL Accredited Electrical Safety Testing Laboratory provide LM-79 Testing for LED Flood Light includes accreditation for Solid State Lighting Luminaires, Total Flux Measurements (Luminous Efficacy) & Solid State Lighting Luminaires, Luminous Intensity Measurements.

The Testing to be conducted is as follows:-

LM-79 Testing on LED Flood lights Testing as per standard

Test to be conducted under LM 79 for LED Flood lights:

1. Measurement of Total Luminous Flux
& Luminous Efficacy
2. Color Characteristics (Chromaticity
Coordinates, Correlated Color
Temperature & Color Rendering Index)
3. Light Intensity Distribution Test

IES LM-79-08 Testing Parameters for LED Flood lights
LM-79 Testing Approved Method: Electrical and photometric Measurements of Solid-state Lighting Product

LM-79 Test Photometric Results for LED Flood lights:

Colorimetric Parameters for LED Flood lights:

  • Chromaticity coordinates: (Chroma x / Chroma y / Chroma u(u’) / Chroma v / Chroma v’)
  • Correlated Color Temperature (CCT)
  • Duv Value
  • Color Ratio
  • Peak Wavelength (nm)
  • Half Bandwidth (nm)
  • Dominant Wavelength (nm)
  • Color Purity
  • Color Rendering Index (CRI – Ra)

Photometric Parameters for LED Flood lights:

  • Total Luminous Flux (Lumens)
  • Luminous Efficacy (Lumens/Watt)
  • Radiant Power (Watts)

Electrical Results for LED Flood lights:

  • Input Power (Watts)
  • Input Voltage (Volts )
  • Input Current (Amps)
  • Power Factor
  • Input Frequency (Hz)

Additional Parameters for LED Flood lights:

  • Stabilization Time (Light and Power) = 60 minutes
  • Test Geometry Configuration = 4π
  • Spectroradiometer = (Lisun LMS-9000A Plus)
  • Ambient Temperature = 25.0°C

Click Here to See Video How to Do LM-79 Testing ?

If you have any Query for LM-79 Testing on LED Flood lights

Contact Now!

Mr. Puneet Sharma M: 08196980555 E: [email protected]

If you are Interested You can Fill out the form below to receive a quote on the LM-79 Testing to get started:

Cable gland Testing Laboratory, Cable Glands Test as per BS 6121, Cable gland Testing IEC- EN 62444- 2010

Posted on

Tests on Cable Glands as per BS 6121 / IEC- EN 62444- 2010

Cable gland Testing Laboratory, Cable Glands Test as per BS 6121, Cable gland Testing IEC- EN 62444- 2010

Searches related to Cable gland Testing laboratory in india, Cable gland Testing Services, Cable gland Test lab, Cable Glands as per BS 6121 / IEC- EN 62444- 2010, Cable Glands Test as per BS 6121, Cable gland Testing bs en 50262, Cable gland Testing bs 6121 standard, en 50262 cable gland Testing, cable gland Testing iec 62444, cable gland Testing bs 6121, CABLE GLAND Testing STANDARDS

ITC India NABL Accredited Electrical Safety Testing Laboratory Service Provider of Cable Glands Testing as per BS 6121 / IEC- EN 62444- 2010, If you are looking for Cable Glands Testing Laboratory in Mumbai, Pune, Maharashtra, Ahmedabad, Gujarat, Bangalore, Karnataka, New Delhi, Baddi,Chennai, Tamil Nadu, Panchkula, Haryana, Ambala, Chandigarh, Ludhiana, Mohali, Punjab, kolkata west Bengal, India you can feel free to contact us.

Cable Gland Testing list Performed by ITCIndia:

  • Cable Retention Testing
  • Cable Anchorage Pull Testing
  • Cable Anchorage Twist Testing
  • Impact Testing
  • Torque Testing
  • Ingress Protection Testing
  • Electrical Continuity Testing
  • Insulation Resistance Testing

                                                                         

Cable Glands Testing Plan as per 62444

Sr.No Clause Test Title
1. 7.1 Marking
2. 8 Construction
3 9 Mechanical properties
4. 9.2 Cable Retention Test
5 9.3 Cable anchorage Test for non-armorud Cable
6 9.4 Cable anchorage Test for armorud Cable
7 9.5 Resistance to Impact
8 10 Electrical properties
9 10.2 Ground Bond
10 10.3.2 Electrical current Test
11 11 Electromagnetic compatibility
12 12 12 External influences (IP) codes
13 12.2 Resistance to corrosion
14 13. Fire Hazard

If you are Interested Kindly Fill out the form below to receive a quote on the Cable Gland Testing to get started:

Contact Now! Puneet Sharma M: 08196980555 E: [email protected]

Provide us more details about your requirement, Please fill out the form below:
To Get Best Quote kindly describe your requirement for ‘ Cable gland Testing’

LM 79 Test Laboratory for LED Street Light

Posted on

LM 79 Test Laboratory for LED Street Light

LM-79 Testing for LED Street Lights

ITC India NABL Accredited Electrical Safety Testing Laboratory provide LM-79 Testing for LED Street Light (45W & 60W) includes accreditation for Solid State Lighting Luminaires, Total Flux Measurements (Luminous Efficacy) & Solid State Lighting Luminaires, Luminous Intensity Measurements.

The Testing to be conducted is as follows(Testing as per standard):-

Test to be conducted under LM 79:

  1. Measurement of Total Luminous Flux & Luminous Efficacy
  2. Color Characteristics (Chromaticity  Coordinates, Correlated Color Temperature & Color Rendering Index)
  3. Light Intensity Distribution Test

 

IES LM-79-08 Testing Parameters,  LM-79 Testing Approved Method: Electrical and photometric Measurements of Solid-state Lighting Product

LM-79 Test Photometric Results:

Colorimetric Parameters:

  • Chromaticity coordinates: (Chroma x / Chroma y / Chroma u(u’) / Chroma v / Chroma v’)
  • Correlated Color Temperature (CCT)
  • Duv Value
  • Color Ratio
  • Peak Wavelength (nm)
  • Half Bandwidth (nm)
  • Dominant Wavelength (nm)
  • Color Purity
  • Color Rendering Index (CRI – Ra)

Photometric Parameters:

  • Total Luminous Flux (Lumens)
  • Luminous Efficacy (Lumens/Watt)
  • Radiant Power (Watts)

Electrical Results:

  • Input Power (Watts)
  • Input Voltage (Volts )
  • Input Current (Amps)
  • Power Factor
  • Input Frequency (Hz)

Additional Parameters:

  • Stabilization Time (Light and Power) = 60 minutes
  • Test Geometry Configuration = 4π
  • Spectroradiometer = (Lisun LMS-9000A Plus)
  • Ambient Temperature = 25.0°C

Click Here to See Video How to Do LM-79 Testing ?

If you have any Query for LED Luminaires Testing, You can Feel free to Contact Us

If you are Interested You can Fill out the form below to receive a quote on the LM-79 Testing to get started:

Contact Now!

Puneet Sharma, M: 08196980555 E: [email protected]

LM-79 Testing | LM-79 Test Approved Methods

Posted on Updated on

LM-79 Testing | LM-79 Test Approved Methods

ITCIndia NABL Approved Electrical Safety Testing Laboratory, ITCIndia Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO 17025 by NABL , has been awarded accreditation by the National Accreditation Board for Testing and Calibration Laboratories (NABL). Under the Energy Efficient Lighting Products Program. This includes LM-79 accreditation for Solid State Lighting Luminaires, Total Flux Measurements (Luminous Efficacy) & Solid State Lighting Luminaires, Luminous Intensity Measurements.

Definition of LM-79 Testing:

LM-79 is one approved method that describes procedures & precautions in performing measurement of LED products.

Scope of IES LM-79 testing:

LM-79 Testing is applied to solid-state lighting products that include the following requirements:

  • LED based products that are integrated control circuit and heat sinks
  • LED based products only requiring AC or DC power supply

And does not cover as bellow:

  • LED products requiring external operating circuits or heat sinks (bare LED chips, package and modules)
  • Fixtures designed for LED products but sold without a light source

 

Electrical Requirements:

  • SSL products work with AC power: voltage, electrical current, power, frequency, power factor
  • SSL products work with DC power: voltage, electrical current, power

Test Condition and Procedures/ LM-79 Procedures and Conditions:

  1. Ambient Conditions

  • Temperature–maintaining at 25℃±1℃ / Maintain temperature at 25 degrees C +/-1 degree C (within 1M)
  • Air Flow—limited/ Limited air flow
  • Mounting–limited thermal transfer

 

  1. Power Supply

  • Voltage regulation to +/- 2%
  • Voltage waveform (harmonic distortion< 3%) / AC wave shape limit to harmonic RMS of 3%
  1. Aging and Stabilization/ Seasoning and Stabilization

  • New SSL products can be put into tested without aging.
  • Before testing, SSL products should work for a certain time to reach up stable working temperature.
  1. Working Orientation/ Testing Orientation

  2. Electrical Settings

  3. Instrumentation

Test Method of Lm-79/ LM-79 Test Methods:

Integrating Sphere and Goniophotometer available to achieve the test report

Integrating Sphere: Integrating sphere systems are used to measure the total luminous flux and color for LM-79. This can be performed with a photometer (total luminous flux) or a spectral radiometer (spectral radiant flux). Utilizing a spectral radiometer and integrating sphere is the preferred method, which derives total luminous flux and color qualities form spectral radiant flux measurements. Click here to see (Video) how to do LM-79 Test with Integrating sphere systems

  • For measuring total luminous flux and color
  • Photometer – Total Luminous Flux
  • Spectral Radiometer (preferred) – Spectral Radiant
  • Flux (to derive total luminous flux and color qualities)

Goniophometer :  Goniophotometer systems are also used for LM-79 testing to measure luminous intensity distribution. The Goniophotometer system tests derive total luminous flux and provide color characteristics including CCT and CRI.

  • For measuring luminous intensity distribution
  • Total luminous flux is derived
  • Provides color characteristics with spectral radiometer including CCT, CRI

Testing Data of IES LM-79/ LM-79 Test Outputs and Calculations:

Photometric Requirements:

 

If you are Interested You can Fill out the form below to receive a quote on the LM-79 Testing to get started:

Contact Now!

Puneet Sharma

M: 08196980555 E: [email protected]

Electric Fence Energizer Testing

Posted on Updated on

Electric Fence Energizer Testing As per IEC 60335-2-79/ IS 302-2-76

Electric Fence Energizer Testing As per IEC 60335-2-79/ IS 302-2-76

If you are looking for Electric Fence Energizer Testing service in India, ITCIndia one of the best Electrical Safety Testing Laboratory Providing Electric Fence Energizer Testing As per IEC 60335-2-79/ IS 302-2-76,  ITCIndia Electrical testing laboratory follow Indian Electricity Rules and Regulatory requirements of the Central and State Government, for safety.

If you are interested for Electric Fence EnergizerTesting,  Please send some details according this:–

  1. Any catalog
  2. Technical specification including – Voltage, wattage,power supply AC/DC etc.
  3. Any Picture to know the size

Get Quotation for testing Fees against standard IEC 60335-2-79/ IS 302-2-76 for Electric Fence Energizer.

Contact Now!
Puneet Sharma
Email: [email protected] | 08196980555