If you are looking for Room Heater testing Laboratory for Room Heater In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam and other city, ITCINDIA NABL Approved Electrical Safety testing Lab Can Help You! ITC India one of the best Room Heater testing Laboratory in India.
We, “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. The Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Applicable Standards:
IEC 60335-2-30
IS 302-2-30
ASTM E1509
Essential Tests:
Protection against access to live parts
Power input and output at operating temperature
Heating
Temperature rise
Leakage current and electric strength
Transient overvoltage
Moisture resistance
Overload protection
Stability and mechanical hazards
Mechanical strength
Provision for earthing
Insulation resistance
Creepage and air clearance
Some important test Results are shown in tabular form
Table A:
Cl. 10.1
TABLE: Power input deviation
P
Input deviation of/at:
P rated
P measured
Allowed Deviation
Remark
230V, 50Hz
2000W
1930W
+5% & -10%
Within limit
Table B:
Cl. 11.8
TABLE: Heating
P
Test voltages (V) :
At 1.15 * 2000W = 2300 W
–
Ambient (°C) :
25°C
–
Thermocouple locations
Temp. Measured (oC)
Max. Rise Temp. (oC)
Max Limit (oC)
a) Internal Wiring
72
47
50
b) External Wiring
64.1
39.1
50
c) Handle
54.5
29.5
60
d) Switch
49
24
30
Table C:
Clause. No.
Test Conducted
Test Conditions
Test requirement
Results
Cl. 13.2
Leakage Current Test
Motor operated appliance: 1.06 times of rated voltage: Between : Each pole of the supply source and the accessible metal part
Shall not exceed 0.75mA
Pass Imea:24µA
Cl. 13.3
High Voltage Test
Test voltage: : 1000 V Test Duration: 1 min.
Test Part: Between live part and screw on the body.
Shall withstand without breakdown
Pass
No flashover or break down occur
Cl. 14
Impulse Test (Transient over voltages)
Transient Overvoltage: 2920V The impulse test voltage is applied three times for each polarity with intervals of at least 1s.
There shall be no flashover.
Pass, No flash over occur.
Cl. 27.5
Earth Contact Resistance Test
Test Current: 25A
Test Part: Between protective earth terminals and accessible metal Part
Calculated Earth Contact Resistance from current & drop in voltage shall not exceed 0.1 Ω)
Pass
Rmea:-22.6mΩ
Table D:
Cl. 29: Clearances, creepage distances and solid insulation
Minimum distance (mm)
Measured distance (mm)
Verdict
Clearances
– Basic insulation (at Rated Impulse Voltage 2500)
1.5mm
>1.5mm
P
Creepage distances
– Basic Insulation (at Working voltage 250V for pollution Degree 3, Material Group IIIa/IIIb)
4mm
>4mm
P
For your better understanding, we are going to show you the Room Heater Test report of latest LED in the following:
If you’re Buyers Demanding for Room HeaterTesting– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
If you are looking for Photometric Testing Laboratory for LED Lighting In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bengaluru, Hyderabad, Surat, Visakhapatnam and other city, ITC India Can Help You! ITC India one of the best Photometric Testing Laboratory in India.
If you’re Buyers Demanding for Photometric Testing for LED Lights– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
Kindly let us know if you have any present or a future requirement we would be happy to share our Services, past work details , samples test report format, client Testimonials ,formal quotation, etc.
If you are looking for Medical Bed Testing Laboratory in India, ITC India Can Help You! ITC India one of the best Medical Bed Testing Service Provider in India. ITCIndia Can do Medical Bed Testing as per IEC 60601-2-52, EN 60601 Standard
If you’re Buyers Demanding for Medical Bed Testing– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
LM-79 is an approved method for taking electrical and photometric measurements of SSL products. It covers total flux (light output), electrical power, efficacy, chromaticity, and intensity distribution. The five required metrics on the LED Lighting Facts label come from LM-79 testing results.
ITCIndia Offering you a complete choice of services which include LM 79 Testing, Safety Testing, Electrical Testing, IEC/EN/IS/BS/ISO Testing, IP testing as per IEC 60529 and Cable Gland Testing.
ITCIndia Laboratory has been awarded accreditation by the NABL under the Energy Efficient Lighting Products Program. This includes LM-79 accreditation for Solid State Lighting Luminaires – Total Flux Measurements (Luminous Efficacy) and Solid State Lighting Luminaires –Luminous Intensity Measurements.
Our accreditation also includes IES LM-80:2008 for Solid State Lighting Luminaires-Lumen Maintenance (SSL Life Tests).
ITCIndia laboratory is also on the LED Lighting Facts Approved Labs List.
ITCIndia can do safety testing against below international standard like
IEC 61010-1 : lab instruments
IEC 60204-1 : COntrol panel
IEC 60595 : LED luminary
IEC 61347 : Lamp control gear
IEC 60950 : Information technology equipments
IEC 60601 : Electromedical equipmets
IEC 60065 : Audio video & similar product
IEC 61439 : Low voltage switchgear & control gear assemblies
IEC 60034 : rotating electrical machine and more contact us for more information…
LM-79 Definition and Scope
IES LM-79 is an approved method for testing electrical and photometric measurements of solid-state lighting products. LM-79 contains procedures for performing reproducible measurements of LEDs properties, including: total flux, electrical power, efficacy and chromaticity.
The scope of LM-79 applies to LED products that incorporate control electronics and heat sinks. This covers complete LED luminaires and integrated LED sources. It does not include bare LED chips or LED based products without a light source.
LM-79 testing requires complete luminaire testing on an absolute photometric basis. Typically lighting products are evaluated on a relative photometric basis, where separate tests are done for lamps an luminaires. However, for solid state lighting products the LED lamps typically cannot be separated from their luminaires. The absolute photometric testing required measures the light distribution and light intensity of the complete luminaire.
LM-79 Procedures and Conditions
Ambient Conditions
Maintain temperature at 25 degrees C +/-1 degree C (within 1M)
Mounting – limit thermal transfer
Limited air flow
Power Supply
AC waveshape limit to harmonic RMS of 3%
Voltage regulation to +/- 2%
Seasoning and Stabilization
Testing Orientation
Electrical Settings
Instrumentation
LM-79 Testing Methods
Integrating sphere systems are used to measure the total luminous flux and color for LM-79. This can be performed with a photometer (total luminous flux) or a spectral radiometer (spectral radiant flux). Utilizing a spectral radiometer and integrating sphere is the preferred method, which derives total luminous flux and color qualities form spectral radiant flux measurements.
Goniophotometer systems are also used for LM-79 testing to measure luminous intensity distribution. The Goniophotometer system tests derive total luminous flux and provide color characteristics including CCT and CRI.
LM-79 Test Outputs and Calculations
Total Luminous Flux
Luminous Intensity Distribution
Electrical Power
Luminous Efficacy
Chromaticity
CCT
CRI
For your better understanding, we are going to show you the LM-79 test report of latest LED in the following:
If you’re Buyers Demanding for LM-79 Testing for LED Lights– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
If you are looking for LED Testing for LED Lights, ITC India Can Help You! ITC India NABL Accredited Laboratory one of the best LED Light Testing Service Provider in India, ITC India Can Do Endurance & Temperature Testing, IP 65 Testing, IP 66 Testing, IP 67 Testing, IS 15885 (P2/S13) Testing, IS 16104 Testing, LM 79/IS 16106 Testing Luminaire Testing, and etc..