Photometry Lab
What is Relative Photometry?
What is relative photometry?
Total Lumen output of a bare lamp is measured in relative photometry for more clarity; the total luminous flux of the lamp is measured separately without the Fixture. In IES LM-80- 08, IES LM 82-12, the relative photometry is used. The purpose is to find light output, Efficacy, color over temperature for light engines.
Relative photometry can measures:
- Total luminous flux of the bare lamp
- Luminous intensity distribution
- Scale the luminous intensity values by the ratio of the measured lamp lumens to the rated lamp lumens.
Some important features regarding relative photometry:
- Relative photometry is performed for luminaries with conventional sources.
- Luminaries test is referenced to the luminous Flux measured for bare lamp.
- The result produced is in the units of candela per rated lumens( cd/rated lm)
- It can also measure the efficiency of luminary.
- Normalize ballast factor, Lamp age.
- Specific lamp performance doesn’t matter
Relative photometry is not used in SSL with integrated lamps due to many reasons:
- The LED‘s are difficult to remove from the Luminaries.
- A large number of LED devices will not work properly without heat sinks provided with luminaries.
- The thermal environment that the LED devices undergo within the luminary is often radically different from the thermal environment it will practice in its “bare lamp” configuration.
If you’re Buyers Demanding for LM-79 Testing– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]
Get Instant Quotations, Fill the Enquiry form:
This entry was posted in LED Testing, LED Tube Light Safety Testing, LM 79 Testing and tagged Absolute photometry and relative photometry, absolute photometry astronomy, Absolute photometry has relative benefits for LED and SSL, aperture photometry, candela, differential vs. absolute photometry, Goniophotometry of LED Luminaires, How to do photometry, how to read photometric data, IES Photometric Testing, LED Testing Standards Overview, List of Nabl Approved Photometric testing lab, List of Nabl Approved Photometric testing lab india, list of nabl approved photometric testing laboratory, List of Nabl Approved Photometric testing labs, Nabl Approved Photometric testing lab, Nabl Approved Photometric testing lab india, Nabl Photometry testing, NABL Testing Labs - NABL & ISO 17025 Certified Lab, photometric measurement, Photometric Measurement of LED Luminaires, Photometric Testing: Lamp - LED - Luminaire Testing, Photometry Lab, photometry pdf, photometry physics, photometry software, Photometry testing, Photometry testing India, Photometry testing lab, PHOTOMETRY TESTING LABORATORIES, Relative and absolute photometry, Relative Photometry - ITCIndia, Searches related to Relative Photometry, Searches related to What is Relative Photometry?, types of photometry, uses of photometry, what does absolute lumens mean.
Photometric Testing for LED Lighting
Photometric Testing for LED Lighting Laboratory
If you are looking for Photometric Testing Laboratory for LED Lighting In India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bengaluru, Hyderabad, Surat, Visakhapatnam and other city, ITC India Can Help You! ITC India one of the best Photometric Testing Laboratory in India.
We, “Institute of Testing and Certification India Pvt. Ltd” are a leading testing company/laboratory having a NABL accreditation under ELECTRICAL , ELECTRONICS & PHOTOMETRY testing with certificate no. T-3509, T-3570 & T-1811. Testing Laboratory is fully equipped with high accuracy Measuring Instruments & trained personal to provide testing and certification Services for Electrical and Electronic equipment’s. The Laboratory is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.
Our lab is totally equipped with following high accuracy testing instruments to provide testing solution for LED Lights as per IES LM 79-08 standards/IS 10322/IS 16102 part 2
- High precision CCD Spectroradiometer with 2.0 MTR integrating sphere
- Type- C Moving Detector Goniophotometer as per IES LM 79-08 standard
- LED power driver tester
What should be the Content of IES LM 79-08 test report: The test report should contain below parameter:
- Total Luminous Flux
- Luminous Intensity Distribution, IES file
- Electrical Power Characteristics( voltage , current , power , PF & Hz)
- Luminous Efficacy (calculated)lm/watt
- Color Characteristics (CRI, CCT…)
Why to choose ITC India:
- Have NABL under photometry attached is the copy
- Very short turnaround time: Max 5 working days(can do in short time also)
- Have local office in Major City
- We are always customer driven
- Lowest testing rate in INDIA
For your better understanding, we are going to show you the Photometric Testing report of latest LED in the following:
Learn more about this Photometric test >
If you’re Buyers Demanding for Photometric Testing for LED Lights– Contact Now!
Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!
Kindly let us know if you have any present or a future requirement we would be happy to share our Services, past work details , samples test report format, client Testimonials ,formal quotation, etc.
Waiting for your earliest positive revert.
Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]
Get Instant Quotations, Fill the Enquiry form:
This entry was posted in LED Testing, Luminaries LED Product Testing, Photometric Testing, Photometric Training and tagged CHINA, ENGLAND, FRANCE, JAPAN, JAPAN Photometric Testing India, LED Luminaire Testing, photometric and optical testing, Photometric Measurement of LED Luminaires, photometric test procedure, photometric test report, Photometric Testing, Photometric Testing Ahmedabad, Photometric Testing Bengaluru, Photometric testing by ITCINDIA, Photometric Testing Chennai, Photometric Testing CHICAGO, photometric testing equipment, Photometric Testing for LED Candle Bulb, Photometric Testing for LED Lighting, Photometric Testing for LED Lights, Photometric Testing Hyderabad, Photometric Testing India, Photometric Testing Kolkata, Photometric Testing Lab ITCINDIA pvt.ltd, photometric testing laboratory, photometric testing labs, Photometric Testing Lamp, Photometric Testing LONDON, Photometric Testing LOS ANGELES, Photometric Testing MOSCOW, Photometric Testing Mumbai, Photometric Testing New Delhi, Photometric Testing NEW YORK, Photometric Testing OSAKA, Photometric Testing PARIS, Photometric Testing Pune, Photometric Testing Report, Photometric Testing SEOUL, Photometric Testing Services, Photometric Testing SHANGHAI, Photometric Testing Surat, Photometric Testing TOKYO, Photometric Testing Visakhapatnam, photometric testing wiki, Photometric Testing's Facility, Photometry Lab, RUSSIA, Searches related to Photometric Testing for LED Lighting, Searches related to Photometric Testing Laboratory, SOUTH KOREA, USA, What does LM 79 refer to?, What is a photometric test?, What is in a psychometric test?, what is photometric testing.