lm 79 testing labs in maharashtra

Are you Looking for Street Light Testing Laboratory in Your Area?

Posted on Updated on

LED Street Light Testing Laboratory ITC India

Are you Looking for Street Light Testing Laboratory in Your Area? then you’re at the right place.On this website  we are not just going to pitch you to hire us for our specialized Street Light Testing  services but also going to provide a lot of valuable information on what, why and how to do Street Light Testing.

If you are looking for Street Light Testing Laboratory for LED Lighting In your Area, ITCIndia One of the Best Electrical Safety testing Laboratory Approved from NABL. ITC India Providing Street Light Testing for Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam, Panchkula, Haryana, Chandigarh, Mohali, Punjab, India and all over the World.

ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing lab having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Lab is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

European Electrical Safety Testing Standards for Street Lights:

Electrical Safety testing services delivered by I.T.C.India are being provided to ensure the safest and reliable product to be delivered at end user by maintaining all the safety norms as per IEC/EN/IS standards.

More products / standards are mentioned below for reference only. the current versions of applicable standard shall be checked prior to testing.

S.no Product Type Standards
1 Electric Signs, Underwater Luminaires IEC/EN 60598-2-1 & IEC/EN 60598-1
2 Dimmers/ Controllers IEC/EN 61058-1/ IEC/EN 61347-2-11 & IEC/EN 61347-1
3 Seasonal/Holiday Decorative Products IEC/EN 60598-2-20 & IEC/EN 60598-1
4 Fluorescent Lamp Ballasts IEC/EN 61347-2-3, IEC/EN 61347-1, IEC/EN 61347-2-8 & IEC/EN 61347-1
5 Photoelectric Switches for Lighting IEC/EN 60669-2-1 & IEC/EN 60669-1
6 Fluorescent Lamp Ballasts IEC/EN 61347-2-3, IEC/EN 61347-1, IEC/EN 61347-2-8 & IEC/EN 61347-1
7 HID Lamp Ballasts IEC/EN 61347-2-9, IEC/EN 61347-1, IEC/EN 61347-2-12 & IEC/EN 61347-1
8 Portable Luminaires IEC/EN 60598-2-4 & IEC/EN 60598-1
9 Dimmers/ Controllers IEC/EN 61058-1/ IEC/EN 61347-2-11 & IEC/EN 61347-1
10 Solid-State Dimming Controls IEC/EN 61058-1
11 Track Lighting Systems IEC/EN 60570
12 Fixed Luminaires IEC/EN 60598-2-1 & IEC/EN 60598-1
13 LED Drivers IEC/EN 61347-2-13 & IEC/EN 61347-1
14 Nightlights IEC/EN 60598-2-12 & IEC/EN 60598-1
15 Stage and Studio Luminaires IEC/EN 60598-2-17 & IEC/EN 60598-1
16 Self-Ballasted Lamps/Lamp Adapters IEC/EN 60968
17 Neon Transformers and Power Supplies IEC/EN 61347-2-10 & IEC/EN 61347-1
18 LED Equipment for Use In Lighting IEC/EN 62031
19 Low Voltage Landscape Lighting IEC/EN 60598-2-1, IEC/EN 60598-1, IEC/EN 60598-2-7 & IEC/EN 60598-1
20 Low-Voltage Lighting Systems IEC/EN 60598-1 & IEC/EN 60598-2
21 Flexible Lighting Products IEC/EN 60598-2-20 & IEC/EN 60598-1
22 Photobiological Safety Lamp and Lamps Systems IEC/EN 62471

Photometric Performance Testing for Luminaires:

ITCIndia offers the most comprehensive Luminaires performance testing suite in the Industry today.Photometric Performance Testing for Luminaires products, no one can you covered like ITC India. With Luminaires performance testing abilities that encompass a wide variety of industries, ITCIndia has the capabilities and expertise to meet your testing Requirements. 

S.no Product Type Standards
1 Electrical and Photometric Testing of Solid-State Lighting Devices IESNA LM-79:2008
2 Luminaire Photometry Testing for IEC Files
3 Compact Fluorescent Lamps IESNA LM-66:2000
4 European Performance Specification EN 12368, EN 12966
5 Incandescent Lamps IESNA LM-45:2000
6 Incandescent Filament Lamps IESNA LM-49:2001
7 Spectroradiometric Measurements IESNA LM-58:1994
8 Lumen Maintenance of LED Light Sources IESNA LM-80:2008
9 ENERGY STAR® Testing of Compact Fluorescent (CFL) Lamps
10 ENERGY STAR® Testing of Integral LED Lamps

Environmental and Mechanical Testing:

ITCIndia offers full Environmental and Mechanical Testing and certification services for LED Lighting luminaires to IEC 60598-2-3 Impact IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by electrical enclosures including luminaires against external mechanical impacts. The Impact IK rating scale identifies the ability of an enclosure to resist impact energy levels measured in joules. IEC 62262 specifies how the enclosure must be mounted for IK Impact and IP Testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of Impact IK rating.

S.no Product Type Standards
1 Ingress Protection Testing (IP Rating) IEC 60529
2 Drop/Impact Testing As Per Client Requirements
3 Mechanical Shock Testing As Per Client Requirements
4 Vibration Testing As Per Client Requirements
5 Dust Testing As Per Client Requirements
6 Moisture Testing As Per Client Requirements
7 Moisture Testing As Per Client Requirements
8 Thermal Cycling/Thermal Shock As Per Client Requirements
9 Humidity Testing As Per Client Requirements
10 Abrasion Testing As Per Client Requirements

EMC Testing For Luminaires:

Electrically powered Luminaires products are more required to be tested for EMC per National and international requirements, and at ITC India can help you to do EMC Testing For Luminaires. EMC Testing For Luminaires demonstrates that your Luminaires products electronic emissions will not affect the normal operation of, nor be affected by, other products within the same environment. ITCIndia One of the Best International EMC testing facilities provider, ITC Engineers perform EMC/EMI Testing For your LED Lights.

S.no Product Type Standards
1 Street Lights, Tube Lights, Down Lights, Lamps, Underwater Luminaires, Seasonal/Holiday Decorative Lights, Fluorescent Lamp, Photoelectric Switches for Lighting, HID Lamp, Portable Luminaires, Track Lighting Systems, Fixed Luminaires, Nightlights, Stage and Studio Luminaires, Self-Ballasted Lamps, LED Equipment for Use In Lighting, Landscape Lighting, Low-Voltage Lighting Systems, Flexible Lighting Products, Photobiological Safety Lamp and Lamps Systems IEC/EN 61547, IEC/EN 61000-3-2, IEC/EN 61000-3-3, IEC/EN 61000-4-2, IEC/EN 61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-11,

Why to choose ITC?

We, ITC India providing service to the client from the last 8 years with 100 % satisfied clients. Being NABL accredited, it is equipped with highly accurate machines, experienced and competent engineers. Customer satisfaction is the quality policy of the company. So, we are here to serve the clients in their testing requirements.

  1. Reasonable Price: Very competitive price, being one of the best on the market. Moreover, this price has no hidden fees.
  1. The quality of our support is unmatched: We take support one step further by tailoring our replies to suit your knowledge, expectations and personality.
  1. We’re passionate about what we do: What sets us apart from the competition is that we’re passionate about the services we provide and quality of support.
  1. Proven track record: We’ve gained a reputation as a reliable and honest company in the last 7 years with most of our customers coming from reference.

If Your Buyers Demanding for Street Light Testing – Contact Now!

Kindly send us the following Details, So that we can provide you quotation for the same:

  1. Product Name, Technical Specifications and Brochure
  2. Product Images
  3. Total Number of samples Required: 2

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

What are LM 79 Test Outcomes?

Posted on

What are LM 79 Test Outcomes?

LM-79 is approved test method for electrical and photometric measurements of Solid State Lighting Products. It describes the procedure in measuring total luminous flux, electrical power, luminous intensity distribution, chromaticity under standard conditions. It covers LED based SSL products with control electronics and heat sink incorporated with AC or DC power supply. This does not include LED chips, LED package or LED module but luminaries (fixtures incorporating light source) as well as integrated LED lamps.

The equipment used in LM-79 is integrated sphere and goniophotometer.

Integrating Sphere                          Goniophotometer

The test report shall list all significant data for each SSL product tested together with performance data. The outcomes of the LM-79 test are:

  • Correction factor applied ( e.g. spectral mismatch, self absorption , intensity distribution etc.)
  • Measured total luminous flux( lumen(lm)), input voltage(v), current(a), power(w), Luminous intensity distribution(cd), efficacy(lm/w)
  • Color quantities( chromaticity coordinates, CCT, CRI )
  • Spectral power distribution
  • Bandwidth of spectoradiometer, if spectral distribution and/or color quantities are reported.
  • Statement of uncertainties (if required)
  • Deviation from standard operating procedures, if any.

Here is the link of a test report issued by our prestigious company. LM 79 Test Outcomes

If you’re Buyers Demanding for LM-79 Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

Photometric Testing Experts

Posted on

Searches related to Photometric Testing Experts, What is Photometric Testing, Photometric Test Procedure, Photometric Test Report, Photometric Testing India, LM-79 Testing Experts, Photometric Testing labs, LED Testing Experts, Photometric Testing for LED Lighting

If you are looking for Photometric Testing Laboratory for LED Lighting In your Area, ITCIndia Electrical Safety testing Laboratory Approved from NABL. ITC India one of the best Photometric Testing Laboratory in India, Mumbai, Chennai, Ahmedabad, New Delhi, Pune, Kolkata, Bangalore, Hyderabad, Surat, Visakhapatnam.

ITCIndia “Institute of Testing and Certification India Pvt. Ltd” are a leading testing lab having a NABL accreditation under ELECTRICAL, ELECTRONICS and PHOTOMETRY testing with certificate no. T-3509, T-3570 and T-1811. ITCIndia Lab is following the procedure as required by International Standard IEC 17025 and is already certified for ISO/IEC 17025.

As the development of LED technology continues to grow and diversify, the need for consistent and standardized testing procedures for LED has become more prevalent than ever. ITCIndia is NABL Accredited laboratory for Photometric Testing for LED Lighting, LM 79 Testing.

Institute of Testing and Certification India Pvt. Ltd has made strides to stay current with the new testing standard LM-79 set forth by the IESNA (Illuminating Engineering Society of North America). In addition, “ITCIndia” testing is now a priority when testing our LED light systems for more reliable results.

ITCIndia Lab has made strides to stay current with the new testing standard LM-79 set forth by the IEC/EN 60598. In addition, ITC INDIA testing is now a priority when testing our LED light systems for more reliable results. Fixtures tested by LM-79 standards will now feature a Lighting Facts label provided through the program created by the IEC/EN.

LM-79 Electrical and Photometric Measurements of Solid-State Lighting Products

Approved method describing procedures and precautions in performing reproducible measurements of LEDs:

  • Total luminous flux
  • Electrical powers
  • Luminous Intensity distribution
  • Efficacy (lm/watt)
  • Chromaticity

How To do Photometric Testing?

Check Our Photometric Testing Scope

Absolute Photometry Basis

  1. LM-79 requires complete luminaire testing
  2. Traditionally, photometric evaluation of lighting products is based on separate tests for lamps and luminaires
  3. For SSL products, LED lamps typically cannot be separated from their luminaire because of heat effects

Relative vs. Absolute Photometry

Relative testing – Lamps of interest and luminaire are measured separately. Then the actual light distribution and intensity of the complete luminaire of interest is derived by normalization of the test data

Absolute testing – The actual light distribution and intensity of the luminaire of interest is measured directly from the complete luminaire.

For your better understanding, we are going to show you the Photometric Test report of latest LED in the following:

Learn more about this Photometric test >

If you’re Buyers Demanding for Photometric Testing– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form: