LM-79 Testing for LED Lights

LM-79 is an approved method for taking electrical and photometric measurements of SSL products. It covers total flux (light output), electrical power, efficacy, chromaticity, and intensity distribution. The five required metrics on the LED Lighting Facts label come from LM-79 testing results.

ITCIndia Offering you a complete choice of services which include LM 79 Testing, Safety Testing, Electrical Testing, IEC/EN/IS/BS/ISO Testing, IP testing as per IEC 60529 and Cable Gland Testing.

ITCIndia Laboratory has been awarded accreditation by the NABL under the Energy Efficient Lighting Products Program. This includes LM-79 accreditation for Solid State Lighting Luminaires – Total Flux Measurements (Luminous Efficacy) and Solid State Lighting Luminaires –Luminous Intensity Measurements.

Our accreditation also includes IES LM-80:2008 for Solid State Lighting Luminaires-Lumen Maintenance (SSL Life Tests).

ITCIndia laboratory is also on the LED Lighting Facts Approved Labs List.

ITCIndia can do safety testing against below international standard like

LM-79 Definition and Scope

IES LM-79 is an approved method for testing electrical and photometric measurements of solid-state lighting products. LM-79 contains procedures for performing reproducible measurements of LEDs properties, including: total flux, electrical power, efficacy and chromaticity.

The scope of LM-79 applies to LED products that incorporate control electronics and heat sinks. This covers complete LED luminaires and integrated LED sources. It does not include bare LED chips or LED based products without a light source.

LM-79 testing requires complete luminaire testing on an absolute photometric basis. Typically lighting products are evaluated on a relative photometric basis, where separate tests are done for lamps an luminaires. However, for solid state lighting products the LED lamps typically cannot be separated from their luminaires. The absolute photometric testing required measures the light distribution and light intensity of the complete luminaire.

LM-79 Procedures and Conditions

LM-79 Testing Methods

Integrating sphere systems are used to measure the total luminous flux and color for LM-79. This can be performed with a photometer (total luminous flux) or a spectral radiometer (spectral radiant flux). Utilizing a spectral radiometer and integrating sphere is the preferred method, which derives total luminous flux and color qualities form spectral radiant flux measurements.

Goniophotometer systems are also used for LM-79 testing to measure luminous intensity distribution. The Goniophotometer system tests derive total luminous flux and provide color characteristics including CCT and CRI.

LM-79 Test Outputs and Calculations

For your better understanding, we are going to show you the LM-79 test report of latest LED in the following:

Learn more about this Lm-79 test >

If you’re Buyers Demanding for LM-79 Testing for LED Lights– Contact Now!

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: ITCIndiaOne@Gmail.Com

Get Instant Quotations, Fill the Enquiry form:

 

20.593684 78.962880
Advertisements

Advertisements