Battery Testing

Are You Looking for Lead Acid Battery Testing Labs In India?

Posted on

Lead Acid Battery Testing Labs In India
Are You Looking for Lead Acid Battery Testing Labs In India?

Are you looking for a Lead Acid Battery Testing lab in India? If you said YES! then you’re at the right blog.

If you are looking for Lead Acid Battery Testing Laboratory in India, ITC India Can Help You! ITC India one of the best Lead Acid Battery Testing Service Provider in India. ITCIndia Can do Battery Testing as per IEC/EN Standard

Lead Acid Battery as per IS 1651

On this blog, I am not just going to pitch you to hire us for our Lead Acid Battery Testing services but also going to provide a lot of valuable information on what, why and how we can do Lead Acid Battery Testing as per IEC/EN IS 1651 Standard. Call on 08264401091/ 08196980555 for Lead Acid Battery Testing laboratories.

Request for Lead Acid Battery Testing Report

Why choose ITCIndia For Lead Acid Battery Testing?

ITCIndia is a leading provider of comprehensive testing services for electrical and LED lighting products. Our global network of technical experts, combined with our state of the art testing laboratories, assure a single source solution for meeting all applicable requirements, standards and voluntary schemes. And ITCIndia technical professionals are actively involved in international advisory boards and standards development activities, ensuring the most up to date knowledge of current and changing requirements.

Represented in over 5 locations in India, ITCIndia has an unsurpassed track record of meeting and exceeding the requirements and expectations of our client companies. The ITCIndia brand and our distinctive blue octagon mark are instantly recognized around the globe as symbols of quality and safety Testing and will increase customer confidence in your brand.

ITCIndia can assist companies in low-cost life testing and evaluating of their products for pre-compliance and compliance testing to schemes such as The Carbon Trust Enhanced Carbon Allowance

If Your Buyers Demanding for  Lead Acid Battery Testing – Contact Now!

Kindly send us the following Details, So that we can provide you with a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward to working with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

 

Are you looking for Stationary Lead Acid Battery Testing?

Posted on Updated on

Are you looking for Stationary Lead Acid Battery Testing?
Are you looking for Stationary Lead Acid Battery Testing?

Stationary Lead Acid Battery

IEC 60896-22 is applicable to:-

  1. All stationary Lead-acid cells
  2. Monobloc batteries of the valve-regulated type
  • For Float charge application: They can be permanently connected to a load and d.c. power supply.
  • In a static location: not generally moved from place to place.

They are incorporated into stationary equipment or installed in the battery room.

These kinds of batteries can be used in

  • Telecom
  • UPS
  • Utility switch
  • Emergency power or similar applications

The objective of IEC 60896-22:- It specifies the methods of tests for all types and construction of valve regulated stationary Lead acid batteries and monobloc batteries.

Does not applicable :

  • lead-acid cells and monobloc batteries used for vehicle engine starting applications
  • solar photovoltaic energy systems
  • general purpose applications

There is a list of tests performed on the batteries for safe operation characteristics, durability Characteristics & Performance Characteristics.

Safe operation characteristics

 

Test Clause Measure Purpose
6.1 Gas emission To determine the emitted gas volume
6.2 High Current Tolerance To verify the adequacy of current conduction

cross- sections

6.3 Short circuit current & d.c internal resistance To provide data for the sizing of fuses in the

exterior circuit

6.4 Protection against internal ignition from external spark sources To evaluate the adequacy of protective features
6.5 Protection against the ground short propensity To evaluate the adequacy of design features
6.6 Content and durability of required markings To evaluate the quality of the markings and the

the content of the information

6.7 Material identification To ensure the presence of material identification

markings

6.8 Valve operation To ensure the correct opening of safety valves
6.9 Flammability rating of materials To verify the fire hazard class of battery materials
6.10 Intercell connector performance To verify the maximum surface temperatures of

the connectors during high rate discharges

Performance characteristics

Test Clause Measure purpose
6.11 Discharge capacity To verify the available capacities at selected

discharge rates or discharge durations.

6.12 Charge retention during storage To provide storage duration data
6.13 Float service with daily discharges To determine cyclic performance under float charge conditions
6.14 Recharge behavior To determine the recovery of capacity or

autonomy time after a power outage

Durability Characteristics

Test Clause Measure purpose
6.15 Service life at an operating temperature of

40 °C

To determine the operational life at elevated temperatures
6.16 Impact of a stress temperature of 55 °C or

60 °C

To determine the influence of high stress

temperatures on cell or monobloc battery life

6.17 Abusive over-discharge To determine the expected behavior when excess capacity is discharged
6.18 Thermal runaway sensitivity To determine the expected times to establish a condition of escalating current and temperature
6.19 Low-temperature sensitivity To determine the sensitivity toward damage induced by electrolyte freezing
6.20 Dimensional stability at elevated internal

pressure and temperature

To determine the propensity of the cell or

monobloc battery to be deformed by internal

pressure and at elevated temperature

6.21 Stability against mechanical abuse of units

during installation

To determine the propensity of the cell or

monobloc battery to fracture or leak when

dropped.

If Your Buyers Demanding for Stationary Lead Acid Battery  Testing – Contact Now!

Kindly send us the following Details, So that we can provide you a quotation for the same:

  1. Product Name, Technical Specifications, and Brochure
  2. Product Images
  3. Total Number of Samples Required: 2

Wish this blog post will be help. If you have any other questions, please feel free to contact us. ITCIndia team looking forward work with you and get better together!

Mr. Puneet Sharma | Call: 08196980555 | E-mail: [email protected]

Get Instant Quotations, Fill the Enquiry form:

Battery Testing Laboratory

Posted on Updated on

ITC India NABL Accredited Laboratory Provide Battery testing service As per IEC: 60896-11, IS 1651 in India

If you have any query regarding Battery Testing and Certification. Kindly send us your testing requirements with the product technical details to submit you our testing charges.

We are waiting for your earliest reply.You can call or write us for any clarification

Puneet Sharma | +91.8196980555 | [email protected] | ITC India Pvt. Ltd

Submit Your Testing Requirements,Please fill out the Enquiry below: